The graphene perfluorinated sulfonic acid cation exchange membrane has added a new type of compound fluorine resin and graphene formula with good vanadium resistance during the casting process. After testing, the use of the new additive mix ratio reduced the penetration of vanadium by more than 80%.
The graphene perfluorinated sulfonic acid cation exchange membrane uses 1000 equivalents of high-quality perfluorinated sulfonic acid ion exchange resin as raw material, and has stable performance, and is doped with an optimal ratio of vanadium-barrier fluorine resin, thereby ensuring high conductivity and low vanadium permeability.
Technical Specifications(Reference Standard):
Item |
Index |
Testing Method |
Thickness Increase |
10% ( 23℃, from 50% RH to water soakage ) |
ASTM756 |
15% ( 100℃, from 50% RH to water soaked ) |
ASTM756 |
|
Length Increase |
10% ( 23℃, from 50% RH to water soakage ) |
ASTM756 |
15% ( 100℃, from 50% RH to water soaked ) |
ASTM756 |
|
Tensile strength |
38 MPa ( 23℃, 50% RH, Isotropy) |
ASTMD882 |
Water content |
4% ( 23℃,relative humidity is 50% ) |
ASTMD570 |
Water Absorption |
50±5% ( 100℃, 1h) |
ASTMD570 |
Electrical conductivity |
0.1 S/cm |
|
Acid Capacity |
0.1 meq/g |
|
Elongation at break |
183% |
ASTMD882 |
Density |
1.98 |
Thickness and Weight:
Thickness(μm) |
Weight(g/m2) |
51 |
100 |
64 |
125 |
76 |
150 |
89 |
176 |
89 |
176 |
102 |
200 |
127 |
250 |
183 |
360 |
254 |
500 |
Remarks:The thickness is approximate number, we do not assure absolute precision. Please contact with our salesman if special thickness is requested.
Applications:
The Perfluorinated Sulfonic Acid Ion-Exchange Membrane is used for vanadium flow batteries.Packing:
Our Perfluorinated Ion-Exchange Membrane has sheet and continuous roll:Sheet material standard size:600mm*600mm;800mm*800mm;1000mm*1000mm
Continuous Roll: 800mm width and 680mm with continuous roll
We can also provide special customized size according to your requirement.
Standard packing is packaging the PIEM in plastic drum or bucket.
Electrodialysis Device for Lab Testing